10. The Air conditioning Loop
10.2.1 Boiling temperature vs pressure The boiling point of the refrigerant governs heat exchanges in the condenser and in the evapora- tor: the refrigerant will evaporate or condense depending on the heat exchange direction.
2. The fluid in the CONDENSER condenses during the thermal exchange with the cooler air from the exterior environment, thereby expelling the heat to the exterior. g Two phase changes (evaporation / condensation) g Two phase changes at two different pressures g Two heat exchanges in two heat exchangers (evaporator / condenser)
1. The fluid in the EVAPORATOR evaporates during the thermal exchange with the hot air from the exterior environment, thereby cooling down the cabin.
LOW PRESSURE SIDE
HIGH PRESSURE SIDE
Absolute pressure (bar)
Boiling temperature (°C)
Absolute pressure (bar)
Boiling temperature (°C)
R134a
2,34 2,53 2,72 2,93 3,15 3,38 3,62 3,88 4,43 5,04 5,72
-6,0°C -4,0°C -2,0°C 0,0°C 2,0°C 4,0°C 6,0°C 8,0°C 12,0°C 16,0°C 20,0°C
6,46 9,12 9,63
24,0°C 36,0°C 38,0°C 40,0°C 42,0°C 44,0°C 48,0°C 52,0°C 56,0°C 60,0°C 70,0°C
10,17 10,72 11,30 12,53 13,85 15,28 16,82 21,17
Evaporator
Condenser
Blower
Cooling fan
Heating the refrigerant initiates its evaporation inside the evaporator
Cooling the refrigerant initiates its condensation inside the condenser